  • PXIe Vector Network Analyzer, 300 kHz to 6.5 GHz

    M9371A - Keysight Technologies

    Pay for only the frequency range you need with a choice of six frequency ranges up to 26.5 GHz Improve accuracy, yield and margins with the best PXI VNA speed, dynamic range, trace noise and stability Add functionality to your test system with a full 2-port VNA that fits in a single PXI slot Address your multiport applications needs by cascading multiple models Increase throughput and lower costs by adding modules in a multi-site configuration

  • PXIe Vector Network Analyzer, 100 kHz to 44 GHz

    M9807A - Keysight Technologies

    Full 2 port VNA on a PXI module with flexible applications

  • PXIe Vector Network Analyzer RF Distributor

    M9340A - Keysight Technologies

    The M9340A PXIe vector network analyzer RF distributor is used in the M9485A PXIe multiport vector network analyzer. The module distributes the source and local signals from the source modules to the receivers.

  • PXI Vector Network Analyzer, 300 KHz To 4 GHz

    M9370A - Keysight Technologies

    The Keysight M9370A PXIe vector network analyzer is a full two-port VNA that fits in just one slot. It can function as a two-port VNA, or with multiple modules can be configured for multiport or multi-site measurements.

  • PXIe Vector Network Analyzer, 300 kHz to 20 GHz

    M9374A - Keysight Technologies

    Pay for only the frequency range you need with a choice of six frequency ranges up to 26.5 GHz Improve accuracy, yield and margins with the best PXI VNA speed, dynamic range, trace noise and stability Add functionality to your test system with a full 2-port VNA that fits in a single PXI slot Address your multiport applications needs by cascading multiple models Increase throughput and lower costs by adding modules in a multi-site configuration

  • Optical Noise Analyzer

    A0040A - SYCATUS Corp

    Optical Noise Analyzer is the industry first solution for evaluation of optical frequency noise of lasers as power spectrum density.

  • Fiber Optic Test Equipment: OTDRs

    Terahertz Technologies Inc.

    A range of state-of-the-art advanced OTDRs,Optical Spectrum Analyzers, and Tunable Laser Sources

  • Lightwave Detector

    N4377A - Keysight Technologies

    The N4377A Lightwave Detector is a USB-powered optical-electrical converter with built-in optical power meter capability. If used with a vector network analyzer or a spectrum analyzer it enables frequency domain applications in photonics.

  • Photolysis Rate Analyzer

    PFS-100 - Focused Photonics Inc.

    , HONO, HCHO etc.) are key indicators for identify status & extent of photochemical pollution.The analyzer is receiving solar radiation by quartz probe and transferring the radiation to spectrum via optical quartz fiber, the spectrum data will be evaluated and compared with reference data with mathematical approach and gives photolytic rate.

  • Laser Spectrum Analyzer

    771 Series - Bristol Instruments, Inc.

    The 771 Series Laser Spectrum Analyzer from Bristol Instruments combines proven Michelson interferometer technology with fast Fourier transform analysis resulting in a unique instrument that operates as both a high-resolution spectrum analyzer and a high-accuracy wavelength meter. With spectral resolution up to 2 GHz, wavelength accuracy as high as ± 0.2 parts per million, and an optical rejection ratio of more than 40 dB, the model 771 provides the most detailed information about a laser’s spectral properties.

  • - Optical / RF Converter

    OPT 80 - Unaohm Start S.r.l.

    Calibrated measurement of the optical power of satellite and terrestrial TV signals distributed in optical fiber Calculation of optical signal losses on distribution Measurement of digital parameters (BER - MER - NM etc.) of optical signals converted into RF Visualization of optical carriers in RF Field Metric Spectrum Analyzer Power Meter Optical Field Meter Display Optical RF Power Supply Line Link Meter (LNB power supply ) Optical LNB power supply 13V 500mA with short circuit and overload managementAcquisition of optical measurements using the field meter Data Logger Option: certification of the OPT80 calibration and optical power measurements

  • Analyzers & Systems

    Guided Wave

    The optical or spectrum analyzer is the brain which transforms the signal collected by the sample interface into actionable information. Guided Wave sample interfaces (probes, flow cells) are designed for use with NIR or UV-Vis fiber optic coupled analyzers. They are designed to be rugged and reliable in harsh chemical and physical process conditions while providing optimal light transmission for long-term reliable measurements. More information is available about specific analyzers on each product page or on the process analyzer product overview.

  • Wavelength Meter

    S-107 - Notice

    Wavelength meter slot module of FOTS system offers two main functions of an accurate wavelength meter and a precise tunable band-pass filter. This accurate instrument, which is based on an internal tunable filter, acts as an optical spectrum analyzer or a wavelength meter as well as a low insertion loss tunable filter. The built-in tunable filter of the module is precisely tuned in C-band and L-band optical communication window by using both electronic and optical controlling methods. User can choose the function of this module depending on his or her applications.

  • Portable Test Platform

    FTB-4 Pro - EXFO Inc.

    The FTB-4 Pro is the latest addition to EXFO’s test orchestration portfolio which transforms business as usual into smarter, scalable network testing that significantly increases operational efficiency and provides vital insights into field operations, network performance and service delivery. The 4 slot modular FTB-4 Pro platform enables a unique combination for 100G commissioning, turn-up and troubleshooting which includes the FTBx-88200NGE 100G Multiservice tester (with iOptics transceiver validation software) and the FTB-5240S-P optical spectrum analyzer. There is no need to carry additional platforms or swap modules for unmatched transport and spectral testing on a single platform that no one in the industry can offer. The versatile FTB-4 Pro platform supports a wide range of modules for field testing, data center interconnect, submarine testing, and lab applications for maximum flexibility and ROI across all phases of the service delivery chain: development, deployment, maintenance and troubleshooting. Module combinations on the FTB-4 Pro can also include iOLM/OTDRs, market leading OLTS for fiber characterization, dispersion solutions and other transport modules all with compatibility with EXFO’s market leading fiber inspection probes.

  • *Pulse Characterization Sensors

    mks Ophir

    Pulse Characterization Sensors provide the ability to see and measure the temporal characteristics of pulsed and CW laser beams. Ophir Fast Photodiode Detectors are designed to convert optical signals into electrical signals which are then measured with third-party instrumentation such as oscilloscopes and spectrum analyzers. Accessories are available to connect to IS6 integrating spheres or fiber optic cables. Attenuating filter accessories are also available to increase their dynamic range. Different models offer silicon, UV enhanced silicon and InGaAs PIN photodiodes, covering a combined spectral range of 193 nm to 1700 nm. Rise times range from 25 picoseconds to 3 nanoseconds. The fast rise times are achieved by an internal reverse bias voltage circuit. Power is supplied by internal batteries and/or an external power supply depending on the model. Detectors should be connected to a 50Ω impedance in order to maintain their nominal rise times. They can be connected to higher impedance loads, but this will result in a significant increase in the rise time. If higher output voltage is required, it is recommended to connect the detector to a trans-impedance amplifier with an Input impedance of 50Ω